METSO-JAMESBURY® VALVCON V-SERIES ACTUATOR 115VAC AND 230VAC

METSO-JAMESBURY® VALVCON V-SERIES ACTUATOR 115VAC AND 230VAC

P/F: ELECTRICAL ACTUATOR “METSO-JAMESBURY” SUPPLY: 115 VAC, AMPS: 0.6 A, DUTY CYCLE: 75% CYCLE TIME: 15 DEC/90 DEG. GE P/N: GE311A5449P005/P006 TAG NO: 20TW-1/3 ELECTRICAL ACTUATOR COMPLETE. P/N: GE311A5449P005 SUPPLIER: METSO-JAMESBURY.
P/F: ELECTRICAL ACTUATOR “METSO-JAMESBURY” SUPPLY: 115 VAC, AMPS: 0.6 A, DUTY CYCLE: 75% CYCLE TIME: 15 DEC/90 DEG. GE P/N: GE311A5449P005/P006 TAG NO: 20TW-1/3 ELECTRICAL ACTUATOR COMPLETE. P/N: GE311A5449P006 SUPPLIER: METSO-JAMESBURY.

JAMESBURY® VALVCON
V-SERIES ACTUATOR
115VAC AND 230VAC

GENERAL
Metso is a leading designer and provider of compact, reliable, electronically controlled electric actuators for valves and dampers. We offer a complete line of Valvcon electric actuators for accurate positioning of dampers and valves in the aerospace, automotive, consumer services, discrete manufacturing, energy, environmental, oil/pipeline, petrochemical, power/utilities, process, recreation, transportation, and water/wastewater industries.

Metso has developed and introduced the industry’s most innovative electric actuator features, including simple “set and go” calibration, intelligent processor-based digital electronics, “plug-in” accessory boards, back-up power, as well as electric actuators designed for remote control, solar-powered applications and two-wire network applications.
Metso has built its reputation and success on the ability to envision, implement, and deliver innovative Valvcon actuator technology products and services to support emerging market requirements. As emerging technologies and market needs continue to evolve, Metso will lead the way with high quality Jamesbury Valvcon electric actuators that exceed industry expectations and further refine the valve actuation process.

115VAC AND 230VAC MODELS*

 

Torque Output (breakaway) Speed (seconds per 90º rotation) Duty Cycle VA Rating Max Running Current at Full Load (True RMS) Max Effective Peak Inrush Current (= .66 x peak inrush)
      115VAC 230VAC 115VAC 230VAC 115VAC 230VAC
150 in lb 8 75% 70VA 115VA .6 amps .5 amps 1.25 amps .924 amps
300 in lb 15 75% 70VA 115VA .6 amps .5 amps 1.25 amps .924 amps
600 in lb 30 75% 70VA 115VA .6 amps .5 amps 1.25 amps .924 amps
1000 in lb 25 75% 92VA 161VA .8 amps .7 amps 1.66 amps 1.29 amps
1500 in lb 40 75% 92VA 161VA .8 amps .7 amps 1.66 amps 1.29 amps
2000 in lb 55 75% 92VA 161VA .8 amps .7 amps 1.66 amps 1.29 amps
2500 in lb 70 75% 92VA 161VA .8 amps .7 amps 1.66 amps 1.29 amps
3000 in lb 75 55% 92VA 161VA .8 amps .7 amps 1.66 amps 1.29 amps

*Notes:
1. The Maximun Current stated above includes all options. If the brake and/or heater & thermostat are not installed, the actual current draws will be less.

HOW TO ORDER – V & LV-SERIES ELECTRIC ACTUATORS (A200-1)

Example: 1 2 3 4 5 6
Sample model code: LV W 1500 C H,I,K,S2 N230AC
LV W 1500 C HIKS2 N230AC
1 Series 4 Board Options*
V V No Entry If Standard
LV LV C Control Board
J Speed Control Timer Board
2 Enclosure U Iso/Readback Board
W Weathertight (NEMA 4/4X)
WX Weathertight & Explosionproof (NEMA 4/4X/7 & 9) 5 Other Options
No Entry If Standard
3 Torque (in lbs) H1 Tropical Heater/Thermostat
150 150  /SPAN> I2 ISO 5211 Compliant Output
300 300 V-Series Only K Brake
600 600  /SPAN> P Feedback Potentiometer
1000 1000 S2 2 Additional Limit Switches
1500 1500 T3 Heater/Thermostat
2000 2000 LV-Series Only Y4 Keyed Output
2500 2500 Z Handwheel
3000 3000
6 Operating Voltage
N115AC 115VAC
N230AC 230VAC
Notes:
* Select only one board option as needed.
1. This heater option activates at or below 90°F and deactivates at 110°F; it is recommended
high-humidity applications.
2. 150-600 in-lb models with option “I” are supplied with a 14mm female square.
(note: without option “I” the female square is 3/4 inch). 1000 in-lb models
with option “I” are supplied with a 19mm female square and 1500-3000 in-lb
models are supplied with a 22mm female square. (note: without option “I” the
female square is 1inch).
3. This heater option activates at or below 40°F and deactivates at 60°F; it is recommended
in applications were temperature may drop below 32°F.
4. 150 – 600 lb-in models with “Y” option are supplied with a 15mm female keyed
output. 1000 – 3000 lb-in models with “Y” option are supplied with a 20mm
female keyed output.