GE Panametrics GM868-1-3EX-10414-22-0

GE Panametrics GM868-1-3EX-10414-22-0

Item Part No&Description Specifications
1.10 GM868-1-3EX-10414-22-0 GM868 General Purpose Flowmeter with RS232 digital port;
capable of measuring flow velocity, actual or standard volumetric
flowrate Note- Determination of standard volumetric flow requires
pressure and temperature inputs (See section H)
 /TD>  /TD> 1-Single channel
 /TD>  /TD> 3-12 to 28 VDC operating voltage
 /TD>  /TD> EX-Aluminum IP66 & Flameproof/Explosionproof enclosure. Suitable
for ATEX IIC environments.
 /TD>  /TD> 1-Two isolated 4 to 20 mA outputs (Standard)
 /TD>  /TD> 0-None
 /TD>  /TD> 4-ModBus digital output only
 /TD>  /TD> 1-Two isolated configurable 4 to 20 mA inputs for pressure or
temperature (Internal 24 VDC supply)
 /TD>  /TD> 4-100 kHz transducer operating frequency
 /TD>  /TD> 22-ATEX II 2 G Ex d IIC T6 Gb (Ta = -50C to 60C). Requires enclosure
option D = EX.
 /TD>  /TD> 0-None
 /TD>  /TD>  /TD>
1.20 223-012 Surge protector for 4-20mA analog output or input
 /TD>  /TD>  /TD>  /TD>  /TD>
2.10 GF868-1-2EX-20A14-2-0-0 GF868 Flare Gas Flowmeter with RS232 digital port; 2 Analog
outputs, capable of determining flow velocity, actual or standard
volumetric flowrate, average molecular weight and mass flow
 /TD>  /TD> 1-Single channel
 /TD>  /TD> 2-220 to 240 VAC operating voltage
 /TD>  /TD> EX-Aluminum IP66 & Flameproof/Explosionproof enclosure. Suitable
for ATEX IIC environments.
 /TD>  /TD> 2-Four isolated 4 to 20 mA outputs
 /TD>  /TD> 0-None
 /TD>  /TD> A-HART communication only
 /TD>  /TD> 1-Two isolated configurable 4 to 20 mA inputs for pressure or
temperature (Internal 24 VDC supply)
 /TD>  /TD> 4-100 kHz transducer operating frequency
 /TD>  /TD> 22-ATEX II 2 G Ex d IIC T6 Gb (Ta = -50C to 60C). Requires enclosure
option D = EX.
 /TD>  /TD> 0-Standard Software
 /TD>  /TD> 0-None
 /TD>  /TD>  /TD>
2.20 223-012 Surge protector for 4-20mA analog output or input
 /TD>  /TD>  /TD>  /TD>  /TD>
3 GC868-1-3EX-10415-0-S-0 GC868 Clamp On Gas Flowmeter with RS232 digital port; capable
of measuring flow velocity, actual or standard volumetric flowrate
with NX19 ‘coarse method’ supercompressibility compensation –
steam and mass flow
 /TD>  /TD> 1-Single channel
 /TD>  /TD> 3-12 to 28 VDC operating voltage
 /TD>  /TD> EX-Aluminum IP66 & Flameproof/Explosionproof enclosure. Suitable
for ATEX IIC environments.
 /TD>  /TD> 1-Two isolated 4 to 20 mA outputs (Standard)
 /TD>  /TD> 0-None
 /TD>  /TD> 4-ModBus digital output only
 /TD>  /TD> 1-Two isolated configurable 4 to 20 mA inputs for pressure or
temperature (Internal 24 VDC supply)
 /TD>  /TD> 5-200 kHz transducer operating frequency
 /TD>  /TD> 0-None / General Purpose, NEMA 4X & IP66. Requires enclosure
option D = 1 or 2.
 /TD>  /TD> S- Stainless steel engraved tag (single line of data)
 /TD>  /TD>  /TD>
 /TD>  /TD>  /TD>